Datasheet -- DR04N02KB7G



Representative photograph, actual product appearance may vary.

Due to regional agency approval requirements, some products may not be available in your area. Please contact your regional Honeywell office regarding your product of choice.
 
DR04N02KB7G
DuraStar Rodless Linear Position Transducer, 101,6 mm [4.0 in] Electrical Travel, Hirschmann GDM Termination, Item Number 9810401
Features
  • Vibration damped element - No wiper bounce in high vibration environments
  • Extended side bearing - Improved life under high misalignment
  • Extruded wiper carrier guides - Smooth operation under large misalignment
  • Rugged ribbed housing - For industrial environment
  • Precious metal wipers - Insures high performance, low noise, no oxidation
  • MystR® plastic elements - Tested up to one billion operations
  • High DC level output - Works with simple contollers
  • High performance bearings - Long life even under side-load conditions
  • Absolute continuous measurement - Accurate position at power-up
Typical Applications
  • Injection molding machines
  • Printing presses
  • Meat packing equipment
  • Drill presses
  • Wookworking machines
  • Cranes
  • Front-end loaders
  • Scales
Description
The DuraStar rodless linear position transducer incorporates over fifty years of MystR® technology into the longest lasting factory-rugged potentiometer. It allows large misalignment of shaft and housing, while providing whisper-quiet operation and smooth, clean signal output. MystR® provides the DuraStar excellent durability, especially in dither operation which is so often the determining factor in a potentiometer's life. It is an excellent replacement unit to reduce maintenance operations.

The rodless side-sealed DuraStar can also be used to replace a rodded potentiometer in contaminated applications to improve performance while providing long life.

Intrinsically safe for Class I, II and III Division I, Groups A, B, C, D, E, F and G for hazardous (indoor/outdoor) NEMA 4 locations. V max.=30 V, I max.=100 mA, Ci=0, Li,=0mH.


DR04N02KB7G
DuraStar Rodless Linear Position Transducer, 101,6 mm [4.0 in] Electrical Travel, Hirschmann GDM Termination, Item Number 9810401
Product Specifications
  Supply Voltage   75 Vdc max.
  Measurement Type   Linear
  Housing Size   250,0 mm [9.84 in]
  Total Mechanical Travel   106,6 mm to [4.2 in]
  Electrical Travel   101,6 mm [4.0 in]
  Starting Force (max.)   0,45 kg [1.0 lb]
  Linearity   less than 0.5 %
  Backlash   0,025 mm [.001 in]
  Shaft Material   Stainless Steel
  Shaft Diameter   M5 x 0.8 Metric thread
  Type of Element   MystR® conductive plastic film
  Housing Style   Anodized Aluminum
  Termination   DIN 43650
  Wiper Current   <1 µA
  Resolution   Infinite
  Operating Temperature Range   -65 °C to 105 °C [-85 °F to 221 °F]
  Vibration   20 g / 0,75 mm (rms) 5 hz to 2 khz
  Shock   50 g 11 ms half sine
  Operating Life   one billion dither operations
  Total Resistance   2,000 Ohms
  Resistance Tolerance   ± 20 %
  Insulation Resistance   1000 MOhm @ 500 Vdc
  Dielectric Strength   1000 V rms
  Weight (Ranges)   0,363 kg to 2,22 kg [0.8 lb to 4.9 lb]
  Sealing   NEMA 4
  UNSPSC Code   41111945
  UNSPSC Commodity   41111945 Linear position sensors
  Availability   Global
  Comments   Note; Mating Connector Included. Options; Electrical Travel, Total Resistance, Linearity
  Series Name   DR Series


DR04N02KB7G
DuraStar Rodless Linear Position Transducer, 101,6 mm [4.0 in] Electrical Travel, Hirschmann GDM Termination, Item Number 9810401
[Dimensions]


DR04N02KB7G
DuraStar Rodless Linear Position Transducer, 101,6 mm [4.0 in] Electrical Travel, Hirschmann GDM Termination, Item Number 9810401
[Circuitry]



DR04N02KB7G
DuraStar Rodless Linear Position Transducer, 101,6 mm [4.0 in] Electrical Travel, Hirschmann GDM Termination, Item Number 9810401

PERSONAL INJURY
DO NOT USE these products as safety or emergency stop devices, or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

 

MISUSE OF DOCUMENTATION
  • The information presented in this product sheet (or catalog) is for reference only. DO NOT USE this document as product installation information.
  • Complete installation, operation and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.